APC AP7921B power distribution unit (PDU) 0U/1U Black 8 AC outlet(s)

AP7921B AP7921B
APC AP7921B power distribution unit (PDU) 0U/1U Black 8 AC outlet(s) APC AP7921B power distribution unit (PDU) 0U/1U Black 8 AC outlet(s)
APC AP7921B power distribution unit (PDU) 0U/1U Black 8 AC outlet(s) APC AP7921B power distribution unit (PDU) 0U/1U Black 8 AC outlet(s)

APC AP7921B power distribution unit (PDU) 0U/1U Black 8 AC outlet(s)

Description

Availability

Integrates with StruxureWare Data Center Expert
An IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network.

Flash Upgradeable
Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released.

Local Current Monitoring Display
The aggregate current draw per rack PDU is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip.

Alarm Thresholds
Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.

Load indicator LED
Indicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits.

Power Delays
Allows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly.

Remote Individual Outlet Control
Remotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).

Network Management Capabilities
Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage rack PDUs from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.

Marketing Features

Power Delays
Allows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly.

Remote Individual Outlet Control
Remotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).

Local Current Monitoring Display
The aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip.

Remote Management Capabilities
Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.

Alarm Thresholds
Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.

Agility

Wide range of input and output connections
Product family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 14.4kW using a single branch whip.

Single input power source
Supply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.

Rack-Mountable
Includes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most - in the racks near the equipment.
Design
PDU typesMetered,Switched
MountingHorizontal/Vertical
Product colourBlack
CertificationcUL Listed, CE, CSA, EN 55022 Class A, EN 55024, EN 61000-3-2, EN 61000-3-3, GOST, IRAM, MIC, UL 60950, UL Listed, VDE, VCCI, REACH
RoHS complianceYes
Rack capacity0U/1U
Ports & interfaces
AC outlets quantity8 AC outlet(s)
AC outlet typesC13 coupler
Power plugC20 coupler
Input connection typeIEC-320 C20
Features
Cable length2.5 m
CertificationcUL Listed, CE, CSA, EN 55022 Class A, EN 55024, EN 61000-3-2, EN 61000-3-3, GOST, IRAM, MIC, UL 60950, UL Listed, VDE, VCCI, REACH
RoHS complianceYes
Management features
MonitoringCurrent,Power,Voltage
Outlet controlLock-out,Recycle,Turn off,Turn on
Ergonomics
Cable length2.5 m
Power
Maximum power3680 W
Nominal input voltage200-230 V
Nominal output voltage208-230 V
Maximum current16 A
Maximum total current draw per phase16 A
Maximum input current per phase16 A
Load capacity3680 VA
AC input frequency50 - 60 Hz
Weight & dimensions
Dimensions (WxDxH)445 x 108 x 44 mm
Weight2.27 kg
Package weight3.45 kg
Package dimensions (WxDxH)470 x 343 x 70 mm
Packaging data
Package weight3.45 kg
Package dimensions (WxDxH)470 x 343 x 70 mm
Packaging content
Packaging contentInstallation Guide, Rack Mounting Brackets, User Manual
Operational conditions
Operating temperature (T-T)0 - 45 °C
Storage temperature (T-T)-25 - 65 °C
Storage relative humidity (H-H)0 - 95%
Operating relative humidity (H-H)0 - 95%
Operating altitude0 - 3000 m
Non-operating altitude1 - 15000 m
UNSPSC Code

39121017

AC outlets quantity

8

Brand

APC

Categories

Batteries, Chargers & Power Supplies

Category

Power Distribution Units (PDUs)

Starting from
€1,051.77 Pack of 1
/
incl. VAT €1,293.68
- +
Compare
Order in the next
Get delivery by see exceptions*
Need more delivery information? Chat

APC AP7921B power distribution unit (PDU) 0U/1U Black 8 AC outlet(s)

AP7921B AP7921B
APC AP7921B power distribution unit (PDU) 0U/1U Black 8 AC outlet(s) APC AP7921B power distribution unit (PDU) 0U/1U Black 8 AC outlet(s)
APC AP7921B power distribution unit (PDU) 0U/1U Black 8 AC outlet(s) APC AP7921B power distribution unit (PDU) 0U/1U Black 8 AC outlet(s)

APC AP7921B power distribution unit (PDU) 0U/1U Black 8 AC outlet(s)

Starting from
€1,051.77 Pack of 1
/
incl. VAT €1,293.68
- +
Compare
Order in the next
Get delivery by see exceptions*
Need more delivery information? Chat

Description

Availability

Integrates with StruxureWare Data Center Expert
An IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network.

Flash Upgradeable
Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released.

Local Current Monitoring Display
The aggregate current draw per rack PDU is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip.

Alarm Thresholds
Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.

Load indicator LED
Indicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits.

Power Delays
Allows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly.

Remote Individual Outlet Control
Remotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).

Network Management Capabilities
Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage rack PDUs from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.

Marketing Features

Power Delays
Allows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly.

Remote Individual Outlet Control
Remotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).

Local Current Monitoring Display
The aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip.

Remote Management Capabilities
Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.

Alarm Thresholds
Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.

Agility

Wide range of input and output connections
Product family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 14.4kW using a single branch whip.

Single input power source
Supply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.

Rack-Mountable
Includes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most - in the racks near the equipment.
Design
PDU typesMetered,Switched
MountingHorizontal/Vertical
Product colourBlack
CertificationcUL Listed, CE, CSA, EN 55022 Class A, EN 55024, EN 61000-3-2, EN 61000-3-3, GOST, IRAM, MIC, UL 60950, UL Listed, VDE, VCCI, REACH
RoHS complianceYes
Rack capacity0U/1U
Ports & interfaces
AC outlets quantity8 AC outlet(s)
AC outlet typesC13 coupler
Power plugC20 coupler
Input connection typeIEC-320 C20
Features
Cable length2.5 m
CertificationcUL Listed, CE, CSA, EN 55022 Class A, EN 55024, EN 61000-3-2, EN 61000-3-3, GOST, IRAM, MIC, UL 60950, UL Listed, VDE, VCCI, REACH
RoHS complianceYes
Management features
MonitoringCurrent,Power,Voltage
Outlet controlLock-out,Recycle,Turn off,Turn on
Ergonomics
Cable length2.5 m
Power
Maximum power3680 W
Nominal input voltage200-230 V
Nominal output voltage208-230 V
Maximum current16 A
Maximum total current draw per phase16 A
Maximum input current per phase16 A
Load capacity3680 VA
AC input frequency50 - 60 Hz
Weight & dimensions
Dimensions (WxDxH)445 x 108 x 44 mm
Weight2.27 kg
Package weight3.45 kg
Package dimensions (WxDxH)470 x 343 x 70 mm
Packaging data
Package weight3.45 kg
Package dimensions (WxDxH)470 x 343 x 70 mm
Packaging content
Packaging contentInstallation Guide, Rack Mounting Brackets, User Manual
Operational conditions
Operating temperature (T-T)0 - 45 °C
Storage temperature (T-T)-25 - 65 °C
Storage relative humidity (H-H)0 - 95%
Operating relative humidity (H-H)0 - 95%
Operating altitude0 - 3000 m
Non-operating altitude1 - 15000 m
UNSPSC Code

39121017